public static class WitsmlCementJob.CementStage.Fluid.PumpSchedule extends Object
Modifier and Type | Method and Description |
---|---|
Value |
getBackPressure()
Return the back pressure of this pump schedule.
|
String |
getComments()
Return the comments of this pump schedule.
|
Integer |
getNStrokes()
Return the n strokes of this pump schedule.
|
Value |
getPumpTime()
Return the pump time of this pump schedule.
|
Value |
getRate()
Return the rate of this pump schedule.
|
Value |
getShutdownTime()
Return the shutdown time of this pump schedule.
|
Value |
getVolume()
Return the volume of this pump schedule.
|
void |
setBackPressure(Value backPressure)
Set the back pressure of this pump schedule.
|
void |
setComments(String comments)
Set the comments of this pump schedule.
|
void |
setNStrokes(Integer nStrokes)
Set the n strokes of this pump schedule.
|
void |
setPumpTime(Value pumpTime)
Set the pump time of this pump schedule.
|
void |
setRate(Value rate)
Set the rate of this pump schedule.
|
void |
setShutdownTime(Value shutdownTime)
Set the shutdown time of this pump schedule.
|
void |
setVolume(Value volume)
Set the volume of this pump schedule.
|
public Value getPumpTime()
Corresponds to the WITSML property eTimPump
:
Elapsed time period during the fluid is pumped.
public void setPumpTime(Value pumpTime)
Corresponds to the WITSML property eTimPump
:
Elapsed time period during the fluid is pumped.
pumpTime
- The pump time to set.
May be null indicating absent or unknown.public Value getRate()
Corresponds to the WITSML property ratePump
:
Rate fluid is pumped. 0 means it is a pause.
public void setRate(Value rate)
Corresponds to the WITSML property ratePump
:
Rate fluid is pumped. 0 means it is a pause.
rate
- The rate to set.
May be null indicating absent or unknown.public Value getVolume()
Corresponds to the WITSML property volPump
:
Volume pumped = eTimPump ratePump.
public void setVolume(Value volume)
Corresponds to the WITSML property volPump
:
Volume pumped = eTimPump ratePump.
volume
- The volume to set.
May be null indicating absent or unknown.public Integer getNStrokes()
Corresponds to the WITSML property strokePump
:
Number of pump strokes for the fluid to be pumped (assumes pump output known).
public void setNStrokes(Integer nStrokes)
Corresponds to the WITSML property strokePump
:
Number of pump strokes for the fluid to be pumped (assumes pump output known).
nStrokes
- The n strokes to set.
May be null indicating absent or unknown.public Value getBackPressure()
Corresponds to the WITSML property presBack
:
Back pressure applied during pumping stage.
public void setBackPressure(Value backPressure)
Corresponds to the WITSML property presBack
:
Back pressure applied during pumping stage.
backPressure
- The back pressure to set.
May be null indicating absent or unknown.public Value getShutdownTime()
Corresponds to the WITSML property eTimShutdown
:
If shutdown event, the elapsed time duration.
public void setShutdownTime(Value shutdownTime)
Corresponds to the WITSML property eTimShutdown
:
If shutdown event, the elapsed time duration.
shutdownTime
- The shutdown time to set.
May be null indicating absent or unknown.public String getComments()
Corresponds to the WITSML property comments
:
Comments and Remarks.
public void setComments(String comments)
Corresponds to the WITSML property comments
:
Comments and Remarks.
comments
- The comments to set.
May be null indicating absent or unknown.Copyright © 2023 Petroware AS - https://petroware.no